Hot Water Temperature Control Unit TCU-W-24-D

  • Request Quote
  • Schedule a Demo
  • Get Financing
  • Sell Yours Here
  • Email to a Friend
  • Print
  • Buy Parts
Hot Water Temperature Control Unit TCU-W-24-D
  •  Specifications
  •  Product Overview
  •  Features
  •  Options
  •  Industry Application

Our temperature control units feature a very robust design loaded with features and value. Operator safety, quick setup and competitive pricing were primary consideration in this design. Available in various sizes and options.

  • Auto exhaust function
  • Combined heating and cooling
  • Durable flanged ball valves
  • E Stop circuit
  • Large easy to read display
  • Multi-stage adjustable heating
  • Outlet & inlet manifold
  • Solid, robust construction
  • Tower light with error alarm

OPTIONAL FEATURES

  • Custom color


OPTIONAL VOLTAGE

  • 380V, 50Hz, 3Ph
  • 480V, 60Hz, 3Ph  (standard)
  • 575V, 60Hz, 3Ph
Item US Standard Metric
Heater 24 kW (x 2) 24 kW (x 2)
Temperature Range 95 - 212 °F 35 - 100 °C
Pump Power 2 HP (x 2) 1.5 kW (x 2)
Pump Flow 47.5 gal/min (x 2) 180 lit/min (x 2)
Heat Medium Outlet 1" NPS (x 4) 25 DN (x 4)
Heat Medium Inlet 1" NPS (x 4) 25 DN (x 4)
Cooling Water Outlet 3/4" NPS (x 2) 20 DN (x 2)
Cooling Water Inlet 3/4" NPS (x 2) 20 DN (x 2)

Temperature control systems are used in a wide variety of industrial applications requiring exact operation and process temperatures. The application of temperature control units spans many unrelated manufacturing industries and process types. This list outlines the main industries.

  • Aerospace
  • Adhesives and resins
  • Automotive
  • Biotechnologies
  • Blow molding
  • Chemical processing/ Distillation
  • Cleanrooms
  • Composites/Engineered materials
  • Compounding
  • Compression/Transfer molding
  • Construction
  • Converting
  • Cosmetics
  • Fermentation
  • Food processing
  • Injection molding
  • Laser and machine cooling
  • Medical
  • Metal finishing, plating, galvanizing
  • Packaging
  • Paints, pigments, dyestuff
  • Pet food processing
  • Petrochemical
  • Pharmaceutical
  • Plastics
  • Printing
  • Pulp and paper
  • Rubber
  • Semiconductor
  • Textiles
  • Thermoforming
  • Vacuum forming
DESCRIPTION
  • Item Temperature Control Unit
  • Model TCU-W-24-D
  • Heat Transfer Fluid Water
  • Type Heating and Cooling
  • Number of Zones 2
  • Heater (per zone) 24 kW
  • Temperature (max) 212 °F / 100 °C
  • Temperature (min) 95 °F / 35 °C
  • Pump Flow(per zone) 47.5 gal/min / 180 lit/min

MAIN FEATURES
  • Heating
  • Cooling
Category